2-Channel Particle Counter

CLiMET CI3100-RS TRIDENT

Real Time Monitoring in critical area

Contact us to learn more about the CLiMET CI3100-RS Trident

Aerosol Generator

CLiMET CI3100-RS TRIDENT

The Trident RS particle counter is a 2-channel particle counter used in continuous monitoring applications in a variety of industries – generally Grade A or B (ISO 5) biopharmaceutical or medical device clean zones. The standard particle sizes are 0.5 µm and 5.0 µm. Designed for fixed continuous monitoring applications with an external vacuum pump, the CI-3100 Trident RS offers a standard flow rate of 1 CFM.

The Trident RS Series is provided with your choice of Power-over-Ethernet (POE) or 24 VDC power.
The CI-3100 Trident RS is compatible with either POE or POE+. This technology injects power and ground onto standard network cabling, thus eliminating the need for wall power. POE is a much sought after technology given safety protocols of some of the larger pharmaceutical and biotechnology producers. Sample data is provided end-users with a choice of either Ethernet Modbus, or Push to FTP CSV file upload; and the Trident model connects to existing network infrastructure. The sample data output is 21 CFR Part 11 compliant, and can be easily uploaded into standard environmental monitoring systems including LIMS software.

Finally, the Trident RS employs new proprietary diagnostics. Climet particle counters have a well known reputation in the industry for providing the lowest out-of-tolerance (OOT) rates on interval calibrations, which are an order of magnitude less than our competitors. Our new patented diagnostic routines provide a much higher level of failure detection against contaminated laser optics, and laser failure, which further reduces the probability of having to conduct a failure investigation.

Aerosol Generator

CLiMET CI3100-RS TRIDENT

Technical specifications

Flow Rate Control:
Critical orifice @ 1.0 cfm (please contact us for other flow requirements)
External Vacuum
15” Hg minimum
Particle Channel Sizes
2 channels 0.5/5 μm (please contact us for other size requirements)
Laser Diode
Optimal balance of long life, stability, and resolution for added accuracy
Cleaning
Compatible with common cleaning and sterilization procedures, including VHP
RH/Temp output
Compatible with RH/Temp probe
Accessories Included
IQ/OQ Docs, manual, USB cable, mounting bracket and Quick Start Guide
Other Accessories Available
stainless steel isokinetic probes, tubing, probe stands, software, validation documentation, customized cabling, power injector, zero count filters and other accessories sold separately.
Alarms
Front Panel LEDs, Light Ring, and output for the CLiMET Trident Light Tower
Other Accessories Available
stainless steel isokinetic probes, tubing, probe stands, software, validation documentation, customized cabling, power injector, zero count filters and other accessories sold separately.
LED Status Indicators
Power, Sample, Alarm, Count, Laser Status, Flow Status, Network FTP, Network Time, Service required and Network Link
Environmental
Operating temperature: 0-37.8⁰ C, 32-100⁰ F Dimensions: 6.4” (W) x 4”(H) x 5.9”(D) (16.26 cm x 10.16 cm x 14.99 cm) 0-95% relative humidity, non-condensing
Compliance
ISO 21501-4; ISO 14644-1; EU GMP, Annex 1; and FDA 21 CFR Part 11