Microbial sampler
CLiMET CI-99
Remote Microbial Sampler
- VHP Compatible, stainless steel enclosure
- Compliant to ISO 14698-1
- Ideal Use: Rabs & Isolators
Contact us to learn more about the CLiMET CI-99
Microbial sampler
CLiMET CI-99
The CI-99 has a stainless steel enclosure. It is an active air microbial sampler deployed in a fixed location, and generally used for monitoring isolators, RABS, and Biological Safety Cabinets (BSCs).
The CI-99 is able to accommodate either industry standard 90 mm petri dishes, or RODAC plates; and is available in either 25 LPM, 1 CFM, or 100 LPM flow rates. The lower flow rates of 25 LPM or 1 CFM are recommended for continuous monitoring applications. Testing has confirmed that up to 3 hours (possibly longer) of continuous sampling with a custom agar fill of 40mL in a 90 mm petri dish is possible. Independent validation is recommended.
The Climet CI-99 microbial sampler is designed and built with the same ruggedness users have to come expect in Climet particle counters. It is the only pharmaceutical grade microbial air sampler that meets and exceeds all requirements AND recommendations of ISO 14698, as well as augmented by requirements in ISO 21501-4.
An expert in manufacturing industrial instrumentation, every new instrument design is drop and vibration tested ensuring end-users can expect up to a decade (and beyond) of reliable operation. This level of ruggedized testing is unique among other manufacturers, and ensures accidents don’t turn into capital appropriation requests or expensive repair bills.
The CI-99 microbial sampler is VHP compatible.
Microbial sampler
CLiMET CI-99
Technical specifications
- VHP Compatible, stainless steel enclosure
- Compliant to ISO 14698-1
- Filtered Exhaust Included
Configurations | CI-99 = 100 LPM microbial sampler with aluminum or 316L Stainless Steel Sample Head Sold Separately. * All models have 304 Stainless Steel Enclosure, RS-232 data interface, and HEPA filtered internal exhaust. Both sampling heads are autoclavable @ 134oC for 20 minutes. |
Performance | Sample Head: Choice of Aluminum or Stainless Steel Sample time to measure a cubic meter : 10 minutes @ 100 LPM Sample Control: CI-99=A continuous sample or variable duty cycle to cover extended monitoring. Flow Rate Control: Electronic, automatic closed loop Cleaning: Compatible with common cleaning and sterilization procedures, including VHP. Flow Rate Alarm: Internal audible alarm, +/-10% of Flow Rate Data Interface: CI-99=Diagnostic web page and control via Ethernet Modbus. IP-54 sealable RJ45 connector CI-99 LEDs: Power, Blower, Error (Flow Rate), Delay, Sampling, and Ethernet (Link & Activity) Sample Media = Industry standard 90 mm petri dish. |
Dimensions & Weight | CI-99: 5.9” (H) x 9.84” (W) x 7.87” (L); weight is 12.45 lbs. (5.6 Kg) |
Environmental | Operating temperature: 0-36⁰C, 32-97⁰F 0-90% relative humidity, non-condensing |